Magnum 6K8-Series Industrial Field Switch Installation and User Guide 03/06)
44
www GarrettCom com
..
The following data has been collected from component manufacturer’s (Agilent’s and
Lucent’s) web sites and catalogs to provide guidance to network designers and installers.
Fiber
Port
Module
Speed,
Std.
Mode
Std.
km
fdx
(hdx)
Wave
-
length
nm
Cable
Size
m
X’mitr
Output
P
T ,
dB
R’cvr
Sens.
P
R ,
dB
Worst
OPB,
dB
Worst*
distance
Km, fdx
typical
OPB,
dB
typical*
distance
Km, fdx
6KP4V-
F10ST
10Mb
FL
Multi-
Mode
2
(2)
850
62.5/125
100/140
50/125
-15.0
-9.5
-19.5
-31
-31
-31
14
19.5
19.5
5
5.9
3.4
17
23.5
13.5
6
7
4.8
6KPV-
MST, MSC
100Mb
FX
Multi-
mode
2
(0.4)
1300
62.5/125
50/125
-20
-23.5
-31
-31
9.0
5.5
3.0
2.0
14
12
5
4
6KPV-SSC
100Mb
FX
Single-
mode
18+
(0.4)
1300 9/125 -15 -31 14
28
17.5
35
6KPV-
SSCL
100Mb
FX
Single-
mode
40
(0.4)
1300 9/125 -5 -34 29
58
32.5
65
6KPV-
MTRJ
100Mb
FX
Multi-
mode
2
(0.4)
1300
62.5/125
50/125
-20
-23.5
-31
-31
9.0
5.5
3.0
2.0
15.8
12.2
5.5
4.0
6KPV-
MLC
100Mb
FX
Multi-
mode
2
(0.4)
1300 62.5/125 -19 -31 12
4
16
5.7
6KPV-SLC
100Mb
FX
Single-
Mode
15+
(0.4)
1310 9/125 -15 -28 11
22
-
-
GBIC-
SXSC
1000Mb Multi-
mode
0.55
850 62.5/125
50/125
-9.5 -17 5.5
2
12.5
4
GBIC-
LXSC10
1000Mb Single-
mode
10
1300 9/125 -9.5 -20 8.5
17
10.5
21
GBIC-
LXSC25
1000Mb Single-
mode
25
1550 9/125 -4.0 -21 15
37.5 17.5
43
GBIC-
ZXSC40
1000Mb Single-
mode
40
1550 9/125 -4.0 -21 15
60 17.5
70
GBIC-
ZXSC70
1000Mb Single-
mode
70
1550 9/125 -3.0 -23 18
90 20.5
102
* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed
over long distances (i.e., in excess of approx. 400 meters) can be achieved only if the
following factors are both applied:
The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the
full-duplex (factory default) setting for 100Mbps fiber ports must be used,
and
The worst-case OPB of the fiber link must be greater than the fiber cable’s
passive Attenuation.
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)