GarrettCom MAGNUM 6KM Switch User Manual


 
Magnum 6KM Mobile Ethernet Switch Installation and User Guide 07/10
41
www GarrettCom com
..
APPENDIX D: AC Power Input
D1.0 Specifications for Magnum 6KM-AC Switches, AC Power input
The AC power input connector on the Magnum 6KM Mobile Switch is located
on the left front of the unit. The power terminals are connected as shown below. The
chassis is “earth” or ground (GND).
Each Magnum Model 6KM-AC Managed Switch requires AC power input, at
100-240VAC Power Input, 47 to 63 Hz (auto-ranging).
The mating power cable connection to the 6KM switch is made utilizing a
RD24, locking, female connector. Simply align the keyed female AC power cable
connector to the 6KM male AC power input connector and twist the threaded lock to
secure.
Standard 6KM male AC Power Input connector:
Pin 1=
+
Pin 2=
-
Pin 3= NC (Not connected)
Pin 4= GND
After confirmation of 6KM-AC model is installed:
1. Connect AC supply line to the unit.
2. Apply power to the supply line.
3. Confirm that the PWR led is illuminated.