1000BASE-ZX, full duplex, single-mode (9μm cable) - >70km
Copper 10/100Mb connector types supported:
Copper Port, M12-type (4-pin, D-key coded)
Copper 1000Mb connector types supported:
Copper Port, M12-type (8-pin, A-key coded)
Fiber Multi-mode connector types supported:
Fiber Port, LC-type, SFF Fiber multi-mode
Fiber Single-mode connector types supported:
Fiber Port, LC-type, SFF Fiber single-mode
LEDs: Per Port (one set at the port)
(see section 5.1.1 for detailed LED configurations)
Operating Environment
Ambient Temperature:
-40° to 195° F (-40° to 85°C) for IEC 60068 Type Test short term rating
-40° to 140° F (-40° to 60°C) for UL60950 and Component Parts rating
Storage Temperature: -60°to 210°F (-50°to 100°C)
Ambient Relative Humidity: 5% to 95% (non-condensing)
Altitude: -200 to 13,000 ft. (-60 to 4000m)
Conformal Coating (humidity protection) optional: Request quote
Alarm Relay Contacts
One NC indicating internal power, one NC software controllable, signals are
accessed via M12 connector pins, “Alarm” port
Packaging
Enclosure: High strength cold rolled steel
Dimensions: 9.0 in H x 2.2 in W x 6.0 in D (in vertical mounting position)
22.7 cm H x 5.5 cm W x 15.2 cm D
Cooling method: Convection, enclosed steel case used as a heat sink, no fans
Weight: 2.1 lbs. (0.95 kg)
IP Rating: 52
DC Power Supply (Internal, floating ground)
DC Power Connector: RD24 locking, male
12VDC Power Input nominal (range 10 to 15VDC)
24VDC Power Input nominal (range 18 to 36VDC)
48VDC Power Input nominal (range 36 to 60VDC)
110VDC Power Input nominal (range 77 to 137VDC)
125VDC Power Input nominal (range 88 to 150VDC)
250VDC Power Input nominal (range 160 to 300VDC)
Power Input for PoE: add up to 15 watts per PoE port to the base unit
power draw