GarrettCom Magnum S14 Switch User Manual


 
S14 Convenient Switches Installation and User Guide (09/04)
6
www GarrettCom com
..
-48V DC internal (range of 36 to 60V DC) t.
Power Consumption: 3 watts typical, 4 watts max.
Note 1: 8-15V DC can be used for dual source DC input
Note 2: Internal DC power floats, user may ground “+” or “-” if desired.
Port Connectors:
RJ-45 Port: Auto-cross(MDIX), 100BASE-TX and 10BASE-T:shielded 8-pin
female. Three RJ-45 ports provided in front, and one on the rear. Supports shielded
(STP) and unshielded (UTP) Cat 3, 4, 5 cable. For POE pass-through option on H
and P models, request quote.
LED Indicators (Dual- front and end, port #4 has front only)
POWER: Steady On when power applied
10/100: = 100Mbps; OFF = 10 Mbps
LK/ACT: Steady On for LINK with no traffic, blinking indicates port
is transmitting / receiving.
F/H: ON = full-duplex, OFF = half-duplex