GBC P70iX Time Clock User Manual


 
7. Specifications
SPECIFICATIONS: Quantum P70iX
Speed: Up to 105 cycles / minute, 60,000 sheets per hour
Sheet size: 5 1/2" to 12", side edge 5 1/2"” to 9"”
Paper Stock: 61 gsm (16#) bond to 300 gsm (140#)
Intermixed weights, flush-cut covers, and standard index tabs
Lift Height: Variable, 5 to 12 sheets of 20# bond (75 gsm)
Stack Height: Up to 14” (approximately 3,500 sheets of 20# bond (75 gsm)
Dimensions: 60”W x 55”L x 52”H (152cm x 140cm x 132cm)
(An authorized technician can separate the Quantum to fit through a
32” doorway.)
Weight: 850 lbs. (386kg)
Power Supply: USA/Canada: 220VAC, 50/60Hz, Single Phase, 2.7 Amps, 0.32 KW, 1,092 BTU/hr
International: 220VAC, 50/60Hz, Single Phase, 2.7 Amps, 0.32 KW, 1,092 BTU/hr
Receptacle Type 6-20R 20A, 250V
Approvals: CSA certified to CAN/CSA-C22.2 No. 60950-00, UL Std No. 60950-00, 3
rd
Ed.
TUV certified to EN 60950:2000
Compliance: Carries CE mark to show compliance with European Union requirement
Die Sets: Interchangeable die sets can be switched in seconds without tools
Noise Level: GBC recommends ear protection for operators of the Quantum P70iX.
Our sound test levels are as follows:
Worst Case Operation (speed 4, C4 Die Set, 20# bond,
lift #9 – 12 sheets):
Sound Pressure Level = LpA = 83.0 dbA
Sound Pressure Impulse = LpAI = 85.2 dbA
Dimensions in meters
30°
Typical Use Operation (speed 2, PB Die Set, 20#
bond, lift #9 – 12 sheets):
Sound Pressure Level = LpA = 78.5 dbA
Sound Pressure Impulse = LpAI = 83.5 dbA
0.25
(9.85”)
ISO 7779 Test method and microphone placement:
1.5M (59.1”) from Feeder,
1.5M (59.1”) high,
0.25M (9.85”) from vertical lead edge of Quantum at con-
trol panel.
Standing operator
Specifications are subject to change without notice
26