Installation
333492B 11
4. Install extension (102) to meter:
a. Loosen extension nut (102a) (F
IG. 4) until it is
completely off tube threads.
NOTE: Do not use PTFE tape or thread sealant on
threads of extension (102). This could cause the fitting
to leak.
b. Thread extension (102) into meter housing as
shown in F
IG. 5 until it bottoms out.
c. Align extension (102) with meter housing and
handle. Hand tighten extension nut (102a).
d. Wrench tighten extension nut (102a).
5. Install nozzle (101):
NOTE: Do not use PTFE tape or thread sealant on
threads of nozzle (101). This could cause the fitting to
leak.
a. Thread nozzle (101) onto extension (102) as
shown in F
IG. 7.
.
b. Use an open-end adjustable wrench on flats of
nozzle bushing (101a) (F
IG. 7) to tighten fitting.
• Only tighten nozzle with wrench on flats of the
nozzle bushing.
• Do not disassemble the bushing from noz-
zle. Disassembly will affect performance of the
nozzle.
FIG. 4
FIG. 5
FIG. 6
102a
102
102
FIG. 7
101
102
101a