Graco 333492B Time Clock User Manual


 
Service
333492B 17
6. Install small retaining ring (43), pointer pin (41) and
pointer spring (42). Install the cover (44). (F
IG. 25).
SDMP8 Preset Meter Counter
Section Repair
Disassembly
NOTE: Do not disassemble the fluid and counting sec-
tions simultaneously. Confirm the fluid section is fully
assembled before removing the counting section.
1. Relieve pressure, page 8.
2. Remove the cover (44), small retaining ring (43),
(F
IG. 26).
3. Remove the needle pointer (41), springs (39) and
pins (40) (F
IG. 27).
4. Remove the large retaining clip (38) and then the
face plate panel (37) (F
IG. 28).
5. Use a 2 mm hex wrench to remove the gear set-
screw (33). Remove the gears (32, 34) (F
IG. 29).
FIG. 25
FIG. 26
44
42
43
41
44
43
FIG. 27
FIG. 28
FIG. 29
41
39/40
38
37
33
34
32