3800g User’s Guide 3 - 11
The breakdown of the command line is shown below:
SEQBLK sequence editor start command
62 code identifier for Code 39
0011 Code 39 code length (9) plus CR suffix (2) = 11
41 start character match for Code 39, 41h = “A”
FF termination string for first code
6A code identifier for Code 128
0012 Code 128 code length (10) plus CR suffix (2) = 12
42 start character match for Code 128, 42h = “B”
FF termination string for second code
69 code identifier for Code 93
0011 Code 93 code length (9) plus CR suffix (2) = 11
43 start character match for Code 93, 43h = “C”
FF termination string for third code
Multiple Symbols
When this programming selection is turned
On
, it allows you to read multiple
symbols with a single pull of the imager’s trigger. If you press and hold the
trigger, aiming the imager at a series of symbols, it reads unique symbols once,
beeping (if turned on) for each read. The imager attempts to find and decode
new symbols as long as the trigger is pulled. When this programming selection
is turned
Off
, the imager will only read the symbol closest to the aiming beam.
No Read
With No Read turned
On
, the imager sends an “NR” to the host if you pull and
release the trigger without reading a code (e.g., bad bar code). If No Read is
turned
Off
, the “NR” will not be sent to the host.
On
* Off
On
* Off