Hand Held Products 3800G Barcode Reader User Manual


 
7 - 26 3800g User’s Guide
EAN/JAN 8 Addenda Separator
When this feature is on, there is a space between the data from the bar code and
the data from the addenda. When turned off, there is no space.
Default = On.
MSI
<Default All MSI Settings>
MSI
MSI Check Character
Different types of check characters are used with MSI bar codes. You can
program the imager to read MSI bar codes with Type 10 check characters.
Default = Validate Type 10, but Don’t Transmit.
When Check Character is set to
Validate and Transmit
, the imager will only read
MSI bar codes printed with the specified type check character, and will transmit
this character at the end of the scanned data.
When Check Character is set to
Validate, but Don’t Transmit
, the unit will only
read MSI bar codes printed with the specified type check character, but will not
transmit the check character with the scanned data.
Off
* On
On
* Off
Validate Type 10 and Transmit
* Validate Type 10, but Don’t
Transmit