4 - 10 IT3800/3900 User’s Guide
Interfunction Delay
This is a delay of up to 495 milliseconds (in multiples of 5) placed between the
transmission of each segment of the message string. You can program up to 99
steps (of 5 ms each). Scan the Interfunction Delay bar code below, then scan
the number of steps, and the SAVE bar code from the inside back cover.
Note: If you make an error while scanning the
digits (before scanning Save), scan Discard on the inside back cover,
scan the Interfunction Delay bar code, scan the correct digits, and Save
again.
To remove this delay, scan the Interfunction Delay bar code, then set the number
of steps to 00. Scan the SAVE bar code from the inside back cover.
Intermessage Delay
This is a delay of up to 495 milliseconds (in multiples of 5) placed between each
scan transmission. You can program up to 99 steps (of 5 ms each). Scan the
Intermessage Delay bar code below, then scan the number of steps, and the
SAVE bar code from the inside back cover.
Note: If you make an error while scanning the digits (before scanning Save),
scan Discard on the inside back cover, scan the Intermessage Delay bar
code, scan the correct digits, and Save again.
To remove this delay, scan the Intermessage Delay bar code, then set the
number of steps to 00. Scan the SAVE bar code from the inside back cover.
Interfunction Delays
Prefix Scanned Data Suffix
1 2345STX HT CR LF
Interfunction Delay
2nd Scan Transmission1st Scan Transmission
Intermessage Delay
Intermessage Delay