...continued
NOTE! Each original holder has it's own unique identification code
(a combination of small rectangular holes at the holder's leading
edge). These codes, combined with the scanner's ability to detect the
feed table position, ensure that the scanner will not operate unless
the feed table position matches the selected original holder.
6. Place the original holder (K) with the slotted tab facing into the
scanner. For transparencies, the flexible magnetic layer must face
upwards. For reflectives, the clear plastic sheet must face upwards.
Make sure that the original holder fits between the appropriate
guides (C) or (D) on both sides of the light table.
7. Slide the holder gently into the slot (E) at the top of the feed table. It
will slip about ½ cm (1/4 inch) into it. Do not press too hard. It slips
in very easily and is held in place by a magnetic clasp. To remove
the holder, simply pull it gently backwards.
8. Lift the top layer of the original holder and place your original (L) as
follows:
• For transparencies, place your original with the emulsion side
down. The original must completely fill the hole with no edges
showing and with a minimum overlap of 2mm along each edge.
Also, no edges of the original must extend past the outer edges of
the holder. Use the grid on the light table (B) to help line up the
image.
• For reflectives, make sure that no part of the original extends past
the edge of the holder. Use the dotted lines printed on the holder
to line up the image. Handle the clear plastic layer only by the
edges to avoid fingerprints. Curl the plastic layer back and slip
the front edge into Flextight's foil holder.
continues...
User's Guide - Flextight 848
Hardware Reference - Flextight 848
17
Operating Instructions
English