HP (Hewlett-Packard) 12076A LAN/1000 LINK Switch User Manual


 

     
NM> TC,08-00-09-00-02-0B<RETURN>
Initiate 802.3 Card Self Test on node 08-00-09-00-02-0B.... [failed]
ERROR: DE00C REPORTING NODE ADR: 08000900020B SAP: F8
Self-test failed
1 1 1 1 0 0 0 0 0 0 0 0 1 0 0 1
R1 R0 R P D I L M N S
bit set to one failure
-------------- -------
R1 RAM
R0 RAM
R RAM
P PROM
D DMA controller
I Interrupt system
L Link controller
M MAU power fuse
N NOVRAM
S 0 = only NOVRAM
1 = other failure
NM>
              