4. Power Up the Disk Array
Turn on the disk array’s power by setting the POWER switch on the back of the unit to ON. The green POWER-ON
LED on the front of the disk array will light up and the fans will rotate.
On a disk array fully loaded with 30 disk modules, allow 8 to 10 minutes for all the disk modules to spin up.
If the BUSY LEDs on the disk drive modules do not light up, check that the disk array’s power cord is properly installed
and connected to the cabinet’s PDU.
Figure 36. Powering up the disk array
5. Power Up the HP NetServers
When the disk array is fully powered up, power up the HP NetServers. After powering up the HP NetServers, verify the
FC I/O adapter, GBIC, and cable installation on each HP NetServer in the cluster by looking at the two LEDs on the FC
I/O adapter. If the LED on the right is on, the FC-AL is complete. If the LED on the left is on, data is being transferred.
POWER
Front of storage system
Back of storage
Note: Fan not shown
for clarity
system