HP (Hewlett-Packard) DL185 Server User Manual


 
Contents 99
Table 11 Hardware Specifications
Item Components
Power Supply unit (PSU) 750W, Redundant power supply
Thermal solution Four system fans
Table 12 Physical Dimensions
Item Description
System board platform ATX (Advanced Technology Extended)
System board dimension 12 in x 13.5 in (304.8mm x 342.9mm)
Server dimensions
Rack
17.63 in x 3.44 in x 27.5 in
448W x 87.5H x 698.7D (mm)
Server weight Basic Configuration ( excludes keyboard and monitor):
20 kg
Table 13 Environmental Specifications
Item Description
Temperature:
Operating
Non-operating
Storage
Wet-bulb temperature
+10 to +35°C (+50 to +95°F)
-30 to 60°C (-22 to 140°F)
-30 to 60°C (-22 to 140°F)
38.7° (101.7°F)
Relative humidity:
Operating
Non-operating
Storage
10% to 90% (non-condensing)
5% to 95%
5% to 95%
Altitude:
Operating
Non-operating
0 to 3049 meters (0 to 10,000 ft)
0 to 9146 meters (0 to 30,000 ft)
Thermal output (maximum operating)
Acoustic emissions
Normal configuration
392 W/hr
LWad: 6.7 Bels
(operating at room temperature)
LWad: 6.7 Bels
(Idle at room temperature)