HP (Hewlett-Packard) DL320 G6 Server User Manual


 
Specifications 89
Specification Value
Weight (maximum
configuration: all hard
drives, power supplies, and
processors installed)
13.60 kg (29.98 lb)
Weight (minimum
configuration: one hard
drive, power supply, and
processor installed)
11.60 kg (25.57 lb)
Power supply specifications
Depending on installed options, the server is configured with one of the following power supplies:
HP ProLiant 400 W Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency 50 Hz to 60 Hz
Rated input current 6 A at 100 VAC
3 A at 200 VAC
Rated input power 572 W at 100V AC input
572 W at 200V AC input
BTUs per hour 1952 at 120V AC input
1952 at 200V to 240V AC
input
Power supply output
Rated steady-state power
400 W at 100V to 120V AC
input
430 W at 200V to 240V AC
input
Maximum peak power
400 W at 100V to 120V AC
input
430 W at 200V to 240V AC
input
HP ProLiant 400 W Redundant Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency 50 Hz to 60 Hz
Rated input current 6 A at 100 VAC
3 A at 200 VAC