HP (Hewlett-Packard) DL320 G6 Server User Manual


 
Specifications 90
Rated input power 450 W at 100V AC input
420 W at 200V AC input
BTUs per hour 1708 at 100V AC input
1640 at 200V AC input
Power supply output
Rated steady-state power
340 W at 100V to 120V AC
input
340 W at 200V to 240V AC
input
Maximum peak power
340 W at 100V to 120V AC
input
340 W at 200V to 240V AC
input
HP ProLiant 460 W Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency 50 Hz to 60 Hz
Rated input current 5.5 A at 100 VAC
2.6 A at 200 VAC
Rated input power 526 W at 100V AC input
505 W at 200V AC input
BTUs per hour 1794 at 100V AC input
1725 at 200V AC input
Power supply output
Rated steady-state power
460 W at 100V to 120V AC
input
460 W at 200V to 240V AC
input
Maximum peak power
460 W at 100V to 120V AC
input
460 W at 200V to 240V AC
input
HP 500 W Power Supply
Specification Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency 50 Hz to 60 Hz
Rated input current 10 A at 100 VAC
5 A at 200 VAC