HP (Hewlett-Packard) DL760 Server User Manual


 
UPS Options
UPS OptionsUPS Options
UPS Options
SNMP Serial Port Card
192189-B21
NOTE:
NOTE: NOTE:
NOTE:
Supports tower and rack UPS XR models ranging from 1000 – 3000VA.
Six Port Card
192185-B21
NOTE:
NOTE: NOTE:
NOTE:
Supports tower and rack UPS XR models ranging from 1000 – 3000VA.
High to Low Voltage Transformer (250VA)
388643-B21
NOTE:
NOTE: NOTE:
NOTE:
Supports R6000 UPS series only. 2.5 amps @ 125 Volts max output across two NEMA 5-15.
Extended Runtime Module, T1000 XR
218967-B21
NOTE:
NOTE: NOTE:
NOTE:
2U each, two ERM maximum.
Extended Runtime Module, T1500 XR/T2200 XR
218969-B21
NOTE:
NOTE: NOTE:
NOTE:
3U each, one ERM maximum.
Extended Runtime Module, R1500 XR
218971-B21
NOTE:
NOTE: NOTE:
NOTE:
2U each, two ERM maximum.
Extended Runtime Module, R3000 XR
192188-B21
NOTE:
NOTE: NOTE:
NOTE:
3U each, one ERM maximum.
Extended Runtime Module, R6000
347224-B21
NOTE:
NOTE: NOTE:
NOTE:
3U each, two ERM maximum.
Extended Runtime Module, R12000 XR, 4U
217800-B21
NOTE:
NOTE: NOTE:
NOTE:
4U each, two ERM maximum.
SNMP-EN Adapter
347225-B21
NOTE:
NOTE: NOTE:
NOTE:
Supports R6000 UPS series only.
Multi-Server UPS Card
123508-B21
NOTE:
NOTE: NOTE:
NOTE:
Supports R6000 UPS series only.
Scalable UPS Card
123509-B21
NOTE:
NOTE: NOTE:
NOTE:
Supports R6000 UPS series only.
Modular PDUs 1U/0U
Modular PDUs 1U/0UModular PDUs 1U/0U
Modular PDUs 1U/0U
(Up to 32 outlets)
NOTE:
NOTE: NOTE:
NOTE:
1U/0U mounting
brackets shipped with
the unit (optimized for 10000
and 9000 series racks).
HP Modular Power Distribution Units (mPDU), Low Volt Model, 24A (100-127 VAC)
252663-D71
NOTE:
NOTE: NOTE:
NOTE:
This mPDU (252663-D71) may also be used to connect the low volt model of the UPS
R3000 XR.
HP Modular Power Distribution Units (mPDU), High Volt Model, 24A (200-240 VAC)
252663-D72
HP Modular Power Distribution Units (mPDU), High Volt Model, 40A (200-240 VAC)
252663-B21
NOTE:
NOTE: NOTE:
NOTE:
This mPDU (252663-B21), 40A model has a hardwired input.
HP Modular Power Distribution Units (mPDU), High Volt Model, 16A (200-240 VAC)
252663-B24
NOTE:
NOTE: NOTE:
NOTE:
This PDU has a detachable input power cord and allows for adaptability to country specific
power requirements. This model may also be used with the high volt UPSs R3000 XR and R6000 For
North America, need to order cable PN 340653-001.
NOTE:
NOTE: NOTE:
NOTE:
Please see the following Modular Power Distribution Unit (Zero-U/1U Modular PDUs)
QuickSpecs for additional options including shorter jumper cables and country specific power cords:
http://h18000.www1.hp.com/products/quickspecs/11041_na/11041_na.HTML
PDU Options
PDU OptionsPDU Options
PDU Options
Third Party Modular PDU Mounting Kit
310777-B21
NOTE:
NOTE: NOTE:
NOTE:
This kit allows you to mount the Modular PDUs in racks other than the 9000/10000 Series
racks (any racks using the standard 19" rail). For more details please refer the Modular PDU
QuickSpecs.
4.5' IEC C 13 to IEC C14 PDU Jumper Cable (1 per pack)
142257-006
4.5' IEC C 13 to IEC C14 PDU Jumper Cable (15 per pack)
142257-007
QuickSpecs
Compaq ProLiant DL760
Compaq ProLiant DL760Compaq ProLiant DL760
Compaq ProLiant DL760
Options
DA - 10813 North America — Version 39 — October 17, 2003