HP (Hewlett-Packard) DL760 Server User Manual


 
OS Support
OS SupportOS Support
OS Support
Microsoft Windows NT® 4.0 Server
Microsoft Windows 2000
Novell NetWare
SCO UnixWare®
LINUX (Red Hat, SuSE, TurboLinux Server, Caldera eServer)
Sun Solaris Intel Platform Edition
Microsoft Windows 2000 Datacenter Edition
NOTE:
NOTE: NOTE:
NOTE:
The Microsoft Windows 2000 Datacenter Edition is available only as part of a Data Center solution.
NOTE:
NOTE: NOTE:
NOTE:
For a more complete and up-to-date listing of supported OS's and versions, please visit our OS Support Matrix at:
ftp://ftp.compaq.com/pub/products/servers/os-support-matrix-310.pdf
.
NOTE:
NOTE: NOTE:
NOTE:
For an up-to-date listing of the latest drivers available for the ProLiant DL760 G2, please see:
http://h18023.www1.hp.com/support/files/server/us/index.html
.
Data Center
Data CenterData Center
Data Center
Data Center services and support offerings are available with Data Center solutions.
Rack Airflow Requirements
Rack Airflow RequirementsRack Airflow Requirements
Rack Airflow Requirements
Rack 9000 and 10000 series Cabinets
The increasing power of new high-performance processor technology requires increased cooling efficiency for rack-
mounted servers. The 9000 and 10000 Series Racks provide enhanced airflow for maximum cooling, allowing these
racks to be fully loaded with servers using the latest processors.
Rack 7000 series Cabinets
When installing a server with processors running at speeds of 550 MHz or greater in Compaq Rack 7000 series racks
with glass doors (165753-001 (42U), and 163747-001 (22U)), the new processor technology requires the
installation of High Airflow Rack Door Inserts (327281-B21 (42U), 327281-B22 (42U 6 pack), or 157847-B21
(22U)) to promote enhanced airflow for maximum cooling.
CAUTION:
CAUTION: CAUTION:
CAUTION:
If a third-party rack is used, observe the following additional requirements to ensure adequate airflow and to
prevent damage to the equipment:
Front and rear doors:
If your 42U server rack includes closing front and rear doors, you must allow 830
square inches (5,350 sq cm) of hole evenly distributed from top to bottom to permit adequate airflow
(equivalent to the required 64 percent open area for ventilation).
Side:
The clearance between the installed rack component and the side panels of the rack must be a
minimum of 2.75 inches (7 cm).
CAUTION:
CAUTION: CAUTION:
CAUTION:
Always use blanking panels to fill all remaining empty front panel U-spaces in the rack. This arrangement
ensures proper airflow. Using a rack without blanking panels results in improper cooling that can lead to thermal damage.
NOTE:
NOTE: NOTE:
NOTE:
For additional information, refer to the Setup and Installation Guide or the Documentation CD provided with the
server, or to the server documentation located in the Support section at the following URL:
http://h18000.www1.hp.com/products/servers/ProLiantdl760/index.html
.
QuickSpecs
Compaq ProLiant DL760
Compaq ProLiant DL760Compaq ProLiant DL760
Compaq ProLiant DL760
Standard Features
DA - 10813 North America — Version 39 — October 17, 2003
Page 6