HP (Hewlett-Packard) DL785 Server User Manual


 
10 Specifications
In this section
“Environmental specification” (page 95)
“Server specifications” (page 95)
Environmental specification
ValueSpecification
Temperature range
10°C to 35°C (50°F to 95°F)
1
Operating
-30°C to 60°C (-22°F to 140°F)
2
Non-operating
28°C (82.4°F)Maximum wet bulb temperature
Relative humidity (noncondensing)
3
10% to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-condensing.
Operating
5% to 95% relative humidity (Rh), 38.7°C (101.7°F)
maximum wet bulb temperature, non-condensing.
Non-operating
Altitude
3050 m (10,000 ft). This value may be limited by the type
and number of options installed. Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
Operating
9144 m (30,000 ft). Maximum allowable altitude change
rate is 457 m/min (1500 ft/min).
Non-operating
1 10° to 35°C (50° to 95°F) at sea level with an altitude derating of 1.0°C per every 305 m (1.8°F per every 1000 ft) above
sea level to a maximum of 3050 m (10,000 ft), no direct sustained sunlight. Maximum rate of change is 10°C/hr
(18°F/hr). The upper limit may be limited by the type and number of options installed.
System performance may be reduced if operating with a fan fault or above 30°C (86°F).
2 Maximum rate of change is 20°C/hr (36°F/hr).
3 Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for
storage corresponds to a pressure minimum of 70 KPa.
Server specifications
ValueSpecification
Dimension
30.58 cm (12.04 in)Height
69.6 cm (27.4 in)Depth
44 cm (17.32 in)Width
72 kg (160 lbs)Weight (maximum
1
)
67 kg (147 lbs)Weight (minium
2
)
High line
3
200 - 240 V ac
Low line
100 - 120 V ac
Input requirement
180 - 264 V ac90 - 132 V acRated input voltage
Environmental specification 95