HP (Hewlett-Packard) GbE2c Switch User Manual


 
Troubleshooting 51
The management network address/mask (if used) does not contain the IP address of the
management station. From the serial console interface, be sure that the Management Network
Address/Mask contains the IP address of the management station.
Password is not accepted by the switch using the
remote console interface immediately after a reboot
Action:
The switch is still working on network convergence. Wait up to 10 seconds for the password to be
accepted.
Cannot connect to the switch console interface
remotely using SSH
Action:
The switch IP address is not configured or correct.
o From the serial console interface, be sure that the switch IP address is configured and valid on
the network.
o Use the correct IP address to establish the SSH connection with the switch.
The setting allowing access to the switch using the SSH interface is disabled.
From the serial console interface, be sure that the SSH interface is enabled and all the settings are
configured correctly.
The management network address/mask (if used) does not contain the IP address of the
management station. From the serial console interface, be sure that the management network
address/mask contains the IP address of the management station.
Cannot connect to the switch SNMP interface
Action:
The switch IP address is not configured or correct.
o From the serial console interface, be sure that the switch IP address is configured and valid on
the network.
o Use the correct IP address to establish the SNMP connection with the switch.
The management network address/mask (if used) does not contain the IP address of the
management station. From the serial console interface, be sure that the management network
address/mask contains the IP address of the management station.
The port activity LEDs continuously indicate activity
after connecting more than one port to another
switch or destination device
Action: