HP (Hewlett-Packard) HP ProLiant DL320 Generation 5 Server Server User Manual


 
Removal and replacement procedures 28
To replace the component, reverse the removal procedure.
When adding hard drives to the server, observe the following general guidelines:
The system automatically sets all drive numbers.
If only one hard drive is used, install it in the bay with the lowest drive number.
Drives must be the same capacity to provide the greatest storage space efficiency when drives are
grouped together into the same drive array.
Optional storage controllers provide support for hot-plug capability and drive LEDs. Controller options
are:
The embedded controller supports non-hot-plug SATA hard drives. Drive LEDs are not supported.
Optional SATA controllers support hot-plug SATA hard drives and drive LEDs.
Optional SAS controllers support hot-plug SAS or SATA hard drives and drive LEDs.
NOTE: ACU does not support mixing SAS and SATA drives in the same logical volume.
Hard drive blanks
Remove the component as indicated.
CAUTION: To prevent improper cooling and thermal damage, do not operate the server unless
all bays are populated with either a component or a blank.
To replace the component, reverse the removal procedure.
SAS/SATA backplane
To remove the component:
1. Power down the server (on page 26).