HP (Hewlett-Packard) n/a Personal Computer User Manual


 
Chapter 3 83
troubleshooting
selftest failures
memory failures
The HP workstation c-class system requires Memory Page Deallocation to be
implemented. This feature allows the workstation to provide information to the operating
system about memory failures.
The HP-UX operating uses information to map out failing memory areas and continue
normal operation. You can use the command memrpt with the detail switch to obtain
information about the Memory Page Deallocation Table (PDT) as well as single-bit errors
logged by the system.
# /usr/sbin/sysdiag Enter
DUI > logtool Enter
LOGTOOL> memrpt detail Enter
The PDT can also be checked using the pdt command in the Service menu of the Boot
Console Handler (refer to “boot console menus” on page 159).
For allowable memory configurations see Chapter 2 of this manual.
INI CC4n SYS BD CPU
n
mem rendez Slave CPU n entering memory
rendezvous, waiting for the monarch CPU
to select a boot device.
TST D000 SYS BD micro controller Firmware is initializing communications
with the system controller.
WRN D004 SYS BD micro not resp Firmware detected a communications
error with the system controller.
INI D005 SYS BD set dom1 fan spd Firmware is initializing communications
with the system controller.
INI D006 SYS BD set dom2 fan spd Firmware is initializing communications
with the system controller.
WRN D007 SYS BD bad microctl cmd Firmware detected a communications
error with the system controller.
FLT D01n SYS/IO fan n: failure! Firmware detected system fan n stopped.
WRN D02n SYS/IO fan n: too slow! Firmware detected system fan n is
running too slowly.
Table 3-2. Chassis Codes for th HP Workstation C-Class
Ostat Code FRU Message Description