HP (Hewlett-Packard) RPC-2 MD01 Switch User Manual


 
RPC SERIES OWNER’S MANUAL
DETAILED OPERATION AND CONFIGURATION
________________________________________________________________________________
47
CONFIGURATION
Configuration can be performed by the
admin user only via the serial port or the
network port. From the RPC Main Menu,
select #3, “Configuration.” The following
menu appears:
Bay Technical Associates
RPC-3 Configuration Menu
MAC Addr: 00.C0.48.05.53.A2
Unit ID: RPC3
Medium Stat: good
Active users: 1
Enter choice from menu, CR to exit
1) . . . IP Address : 0.0.0.0
2) . . . Subnet Mask : 0.0.0.0
3) . . . Gateway : 0.0.0.0
4) . . . Unit ID : RPC-3
5) . . . Access
6) . . . Outlets
7) . . . Exit
IMPORTANT: N
etwork parameters, such as IP Address, require
a Unit Reset before any changes will take affect. Other
configuration changes will be immediately implemented upon
accepting changes at the end of the configuration procedure. Exit
all menus by pressing <cr>.
IP Address
The IP Address consists of four bytes, each
byte ranging from 0 to 255. This parameter
must be programmed before the RPC can be
accessed on the network.
From the configuration menu, select #1, “IP
Address.” The RPC responds:
Enter IP address in dotted decimal form:
Enter the IP Address (Example:
200.4.3.50), followed by a carriage return.
Upon entry of a carriage return, the RPC
resumes the configuration menu.
Default IP