HP (Hewlett-Packard) XM600 Personal Computer User Manual


 
3 Troubleshooting Your HP PC Workstation
Using HP MaxiLife to Diagnose Problems
54
Using HP MaxiLife to Diagnose Problems
Your HP LCD can help you to diagnose problems with your PC Workstation,
even when you are unable to get your system and monitor working properly.
Pre-Boot Checks When you press your PC Workstation’s on/off button, HP MaxiLife will check
your system before it initiates the start-up sequence. The pre-boot diagnostic
tests are run in order of priority with respect to their importance to computer
functions. The first detected error displays a message on the LCD status panel.
If this happens, one of the following screens could appear.
Check that the processor is
correctly inserted in CPU slot.
Check the power supply and
power cable connections.
Check that the system board is
connected.
CPUSocket
ERROR !
Power Supply
ERROR !
Board PLL
ERROR !
No installed RDRAM
modules.
Check that RDRAM
continuity modules are
installed.
No RIMM
ERROR !
Contin Module
ERROR !
T
he 32 device limit per
RDRAM has been exceed.
RIMM Devices
ERROR !
The RDRAM modules
installed have incompatible
speed ratings.
RIMM Speed
ERROR !
Check that the memory
modules are correctly
installed.
Memory Error
ERROR !