HP (Hewlett-Packard) xw9300 Computer Hardware User Manual


 
System Management
Desktop Management 69
Clearing Passwords
If you forget your password, you cannot access the workstation. Refer to “Additional Password Security
and Resetting CMOS” on page 203 for instructions on clearing passwords.
Hood Sensor (Smart Cover Sensor)
The hood sensor is a combination of hardware and software technology that can alert you when the
workstation side access panel has been removed. There are three levels of protection, as described in the
following table.
Setting the hood sensor protection level
To set the hood sensor protection level:
1. Turn on or restart the workstation.
2. As soon as the workstation is turned on, press and hold the F10 key until you enter Computer Setup.
Press Enter to bypass the title screen, if necessary.
NOTE: If you do not press the F10 key at the appropriate time, you must restart the computer and press
and hold the F10 key again to access the utility.
If you are using a PS/2 keyboard, you might see a Keyboard Error message—disregard it.
3. Select Security > Smart Cover > Cover Removal Sensor, then side access panel, and follow
the on-screen instructions.
French ! Norwegian - Turkish .
French
Canadian
é Polish - U.K. English /
German - Portuguese - U.S. English /
*For Bosnia-Herzegovina, Croatia, Slovenia, and Yugoslavia
Table 3-14 National Keyboard Delimiter Characters
Table 3-15 Hood Sensor Protection Levels
Level Setting Description
Level 0 Disable Hood sensor is disabled (default).
Level 1 Notify User When the workstation is restarted, the screen displays a
message indicating that the workstation side access panel
has been removed.
Level 2 Password When the workstation is restarted, the screen displays a
message indicating that the workstation access panel has
been removed. You must enter the setup password to
continue.
This option is only available if an administrator password
is set.
NOTE: These settings can be changed using Computer Setup.