Hitachi CP-S225 Projector User Manual


 
25
ENGLISH
The LAMP indicator is also red when the lamp unit reaches high temperature.
Before replacing the lamp, switch power OFF, wait approximately 20 minutes, and switch power
ON again. If the LAMP indicator is still red, replace the lamp.
NOTE
Replacing the lamp
All projector lamps will wear out eventually. If used for long periods of time, the image could become
darkened, and the color contrast could be impacted as well. We recommend that you replace your lamps
early. If the LAMP indicator turns red, or a message prompts you to replace the lamp when you power up
the projector, the lamp needs to be replaced. (See "Related Messages" (Vol.2 ) and "Regarding the
Indicator Lamps" (Vol.2 ) for details.)
1
Turn off the projector, and unplug the
power cord. Allow the lamp bulb to cool
for at least 45 minutes, and prepare a
new lamp (sold separately: DT00401 for
CP-S225/DT00461 for CP-X275)
5
Insert the new lamp, and tighten the 1
screw firmly to lock it in place
Also steadily push the opposite side of the
screwed side of the
lamp into the unit.
6
Replace the lamp
cover, and tighten
the 2 screws firmly
to lock it in place
7
Slowly turn the projector so that
the top is facing up
2
After making sure that the projector has
cooled adequately, slowly flip over the
projector, so that the bottom is facing up
3
Unscrew the 2
screws, and
remove the
lamp cover
4
Unscrew the 1 screw, and slowly pull
out the lamp by the handle
Be careful not to touch the inside of the lamp case.