Hitachi CP-RS56 Projector User Manual


 
48
Troubleshooting
Regarding the indicator lamps
Lighting and ashing of the POWER indicator, the LAMP indicator, and the TEMP
indicator have the meanings as described in the table below. Please respond
in accordance with the instructions within the table. If the same indication is
displayed after the treatment, or if an indication other than the following is
displayed, please contact your dealer or service company.
POWER
indicator
LAMP
indicator
TEMP
indicator
Description
Lighting
In Orange
Turned
off
Turned
off
The projector is in a standby state.
Please refer to the section “Power On/Off”. (
17)
Blinking
In Green
Turned
off
Turned
off
The projector is warming up.
Please wait.
Lighting
In Green
Turned
off
Turned
off
The projector is in an on state.
Ordinary operations may be performed.
Blinking
In Orange
Turned
off
Turned
off
The projector is cooling down.
Please wait.
Blinking
In Red
(discre-
tionary)
(discre-
tionary)
The projector is cooling down. A certain error
has been detected.
Please wait until the POWER indicator nishes blink,
and then perform the proper response measure using
the item descriptions below as reference.
Blinking
In Red
or
Lighting
In Red
Lighting
In Red
Turned
off
The lamp does not light, and there is a
possibility that interior portion has become
heated.
Please turn the power off, and allow the unit to cool
down at least 20 minutes. After the projector has
sufciently cooled down, please make conrmation of
the following items, and then turn the power on again.
• Is there blockage of the air passage aperture?
• Is the air lter dirty?
• Does the peripheral temperature exceed 35°C?
If the same indication is displayed after the treatment,
please change the lamp by referring to the section
“Lamp”. (
42)
Blinking
In Red
or
Lighting
In Red
Blinking
In Red
Turned
off
The lamp cover has not been properly xed
(attached).
Please turn the power off, and allow the unit to cool
down at least 45 minutes. After the projector has
sufciently cooled down, please make conrmation
of the attachment state of the lamp cover. After
performing any needed maintenance, turn the power
on again. If the same indication is displayed after
the treatment, please contact your dealer or service
company.