Honeywell 1250g Scanner User Manual


 
10 - 4
Standard Cable Pinouts
RS485 Output
USB
10 Pin RJ41 Modular Plug
connects to the scanner handle
1 Cable shield
2 Cable select
3 Supply ground
4 Transmit data
5 Receive data - serial data to scanner
6
7+5V power
8 Transmit Enable
9
10
Note: RS485 signal conversion is performed in the cable.
Pin assignments are not compatible with Honeywell legacy products.
Use of a cable with improper pin assignments may lead to damage to
the unit. Use of any cables not provided by the manufacturer may
result in damage not covered by your warranty.
10 Pin Modular Plug
connects to the scanner handle
1 Cable shield
2 Cable select
3 Supply ground
4
5
6
7+5V power
8
9Data +
10 Data -
Note: Pin assignments are not compatible with Honeywell legacy products.