Honeywell MS5100 Scanner User Manual


 
21
Symptoms Possible Causes Solution
The unit scans
but the data is
not correct.
The unit’s
configuration is not
correct.
Make sure that the proper PC type
AT, PS2 or XT is selected. Verify
the correct country code and data
format is selected. Adjust the
inter-character delay symptom.
The unit is
transmitting
each character
twice.
The unit’s
configuration is not
correct.
Increase the interscan code delay
setting. Adjust whether the F0
break is transmitted.
It may be necessary to try this in
both settings.
Alpha
characters show
as lower case.
The computer is in
Caps Lock mode.
Enable the Caps Lock detect
feature of the scanner to detect
whether the PC is operating in
Caps Lock.
Everything
works except for
a couple of
characters.
These characters
may not be supported
by that country’s key
look up table.
Try operating the scanner in Alt
mode.
RS232 Interface
The unit
powers-up OK
and scans OK
but does not
communicate
properly to the
host.
The com port at the
host is not working or
not configured
properly.
Check to make sure the baud rate
and parity of the scanner and the
port match and that the
configuration is looking for
“RS232” data.
The cable is not
connected to the
proper com port.
Check to make sure the unit is
connected to the correct com port
on the host device.
The host is
receiving data
but the data
does not look
correct.
The scanner and host
may not be
configured for the
same interface
parameters.
Check the scanner and the host
are configured for the same
interface parameters.
Characters are
being dropped.
Inter-character delay
needs to be added to
the transmitted
output.
Add some inter-character delay to
the transmitted output by using
the MetroSelect Single-Line
Configuration Guide.