31
DESIGN SPECIFICATIONS
MECHANICAL
Length: 198 mm (7.8")
Width: Handle - 45 mm (1.8"), Head - 78 mm (3.1")
Depth: 40 mm (1.6")
Weight: 149 g (5.25 oz)
ELECTRICAL
Input Voltage: 5VDC ± 0.25V
Power:
Operating = 0.825 W typical
Standby = 0.600 W typical
Current:
Operating = 165 mA @ 5VDC typical
Standby = 120 mA @ 5VDC typical
DC Transformers: Class 2; 5.2V @ 1A
For regulatory compliance information see pages 3739.
ENVIRONMENTAL
Temperature:
Operating = 0°C to 40° (32° to 104°F)
Storage = -40°C to 60°C (-40°F to 140°F)
Humidity: 5% to 95% relative humidity, non-condensing
Light Levels: Up to 4842 Lux (450 footcandles)
Shock: Designed to withstand 1.5 m (5 ft.) drops
Contaminants: Sealed to resist airborne particulate contaminants
Ventilation: None required