Honeywell VoyagerGS 9590 Series Scanner User Manual


 
12
SCANNER INSTALLATION
Additional Settings for EAS Equipped Models
All MS9590 models equipped with EAS capabilities have an EAS designation in
their model numbers (example: MS9590-38-EAS). The cable supplied with these
units will have additional wires for Checkpoint Device connections.
Figure 10. EAS Cable Samples
SW1 and SW2 are the switch banks inside the Checkpoint Device that set the
deactivation range. The following is a list of Checkpoint recommended switch
bank settings.
Checkpoint Recommended Switch Bank Settings
SW1 SW2
Switches 1, 4, 5, and 6 ON Switches 1, 4, 5, and 6 ON
Switches 2 and 3 OFF Switches 2 and 3 OFF
Figure 11 shows the location of the
EAS deactivation area.
It is important to pass the entire tag
through this area to deactivate the
security tag.
Figure 11. EAS Deactivation Area