IBM 310ED Personal Computer User Manual


 
Error
Code
Message FRU/Action in Sequence
10XXX CPU or System
board error
1. CPU
2. System board
11XXX Pointing device
error
1. TrackPoint board FPC
cable
2. TrackPoint board
3. Keyboard
4. System board
PCMCIA
X
XXXX
PCMCIA error 1. Replace PC Card
2. PCMCIA slots
assembly
3. System board
Running Fan Diagnostics Program
The system is equipped with sensors to protect against
system overheating. By setting video controller and
processor thermal thresholds, the system can turn on the
cooling fan or shut down automatically when temperatures
reach the defined threshold parameters.
Systems experiencing frequent auto sensor shutdown may
need to reset the thermal sensor threshold (refer to
“Setting Thermal Sensor Threshold”) and execute the fan
test to ensure the cooling fan is operating normally.
Follow the steps below to use Fan Diagnostics Program:
1. Boot from the Diagnostic Program Diskette.
2. Select Fan Diagnostics from PC DOS 7.0 Startup
Menu.
3. Follow the instruction on screen to execute fan
diagnostics.
Note: If test failed, try reseating the fan connector or
replacing the fan.
Utility Program Diskette
The Utility Program Diskette contains a variety of programs
as further explained in this section.
Setting Thermal Sensor Threshold
The system is equipped with sensors to protect against
system overheating. By setting video controller and
processor thermal thresholds, the system can turn on the
cooling fan or shut down automatically when temperatures
reach the defined threshold parameters.
Systems experiencing frequent auto sensor shutdown may
need to reset the thermal sensor threshold and execute
the fan test to ensure the normal operation of the cooling
fan (refer to “Running Fan Diagnostics Program”).
Follow the steps below to set thermal threshold:
ThinkPad 310, 310D, 310E, 310ED (2600)
29