Set System Resume Timer
Input Field
Major Function Number - 34h
Minor Function Number - 3h
Parameter 1 - Reserved
Parameter 2 - Reserved
Parameter 3 - Reserved
Parameter 4 - TOD of Resume Timer (BCD format)
Bit 7- - Seconds ( - 59)
Bit 15-8 - Minutes ( - 59)
Bit 23-16 - Hours ( - 23)
Bit 31-24 - Reserved
Parameter 5 - Date of Resume Timer (BCD format)
Bit 7- - Day (1 - 31)
Bit 15-8 - Month (1 - 12)
Bit 23-16 - Year ( - 99)
Bit 3-24 - Reserved
Bit 31 - Resume Date Validation
= - Valid (Specified day)
= 1 - Invalid (Every day)
Output Field
Return Code - Error Status
Auxiliary Return Code - Reserved
Parameter 1 - Reserved
Parameter 2 - Reserved
Parameter 3 - Reserved
Parameter 4 - Reserved
Parameter 5 - Reserved
A-50 ThinkPad 560/560E SMAPI BIOS