1. Bring-up failure
2. Run-time non-recoverable failure
3. Run-time recoverable failure
4. Group integrity failure
5. Non-repeat-gardable error. The resource may be reconfigured on the next boot.
An error status of 00 (for example, 3.16(00)) indicates that the memory DIMM has
not had any errors logged against it by the service processor.
To change the memory configuration, select the number of the memory DIMM. The
memory DIMM state will change from configured to deconfigured or from
deconfigured to configured.
In the previous example menu, each line shows two DIMMs and indicates whether
they are configured.
To enable or disable Memory Repeat Gard, use menu option 77 of the Processor
Configuration/Deconfiguration Menu.
The failure history of each DIMM is retained. If a DIMM with a history of failures is
brought back online by disabling Repeat Gard, it remains online if it passes testing
during the boot process. However, if Repeat Gard is enabled, the DIMM is taken
offline again because of its history of failures.
v Power Control Network Utilities Menu
POWER CONTROL NETWORK UTILITIES MENU
1. Lamp Test for all Operator Panels
2. Display I/O Type
3. Change I/O Type
98. Return to Previous Menu
0>
Lamp Test for All Operator Panels
Selecting this option tests the media drawer operator panel’s indicators by causing
them to blink on and off for approximately 30 seconds.
Display I/O Type
This option is not available on this system.
Change I/O Type
Use this option to change the I/O type after a service action or configuration
change, if the I/O type is incorrect. If this option is chosen, you will be asked to
make the following entries:
1. For the I/O drawer address, type 1.
2. For the I/O type, type A3.
Chapter 3. Using the Service Processor 49