Technical information
Specified operating environment
Physical specifications
Rack-Mount:
Width: 440 mm (19.0 in)
Depth: 706 mm (27.8 in)
Height: 89 mm (3.5 in)
Weight (Maximum configuration): Power 710 -- 28.2 kg (62 lbs)
Power 730 -- 29.5 kg (65 lbs)
Operating environment
• Temperature: (nonoperating) 5° to 45°C (41° to 113°F); recommended
temperature (operating) 18° to 27°C (64° to 80°F); allowable operating
temperature 5° to 35°C (41° to 95°F)
• Relative humidity: Nonoperating 8% to 80%; recommended 5.5°C (42°F) dew
point to 60% RH and 15°C (59°F) dew point
• Maximum dew point: 28°C (84°F)(operating)
• Operating voltage: 100 to 127 or 200 to 240 V ac (Power 710); 200 to 240 V ac
(Power 730);
• Operating frequency: 47/63 Hz
• Maximum measured power consumption:
– Power 710 -- 650 watts (maximum)
– Power 730 -- 1100 watts (maximum)
• Power factor: 0.98
• Thermal output:
– Power 710 -- 2,218 Btu/hour (maximum)
– Power 730 -- 3,754 Btu/hour (maximum)
• Power-source loading
– Power 710 -- 0.663 kVa (maximum configuration)
– Power 730 -- 1.122 kVa (maximum configuration)
– Maximum altitude: 3,050 m (10,000 ft)
Note: The maximum measured value is the worst case power consumption
expected from a fully populated server under an intensive workload. The maximum
measured value also accounts for component tolerance and non-ideal operating
conditions. Power consumption and heat load vary greatly by server configuration
and utilization. The IBM Systems Energy Estimator should be used to obtain a heat
output estimate based on a specific configuration
http://www-912.ibm.com/see/EnergyEstimator