POST Error Code FRU/Action
08X
Check SCSI terminator installation.
1. SCSI Cable
2. SCSI Terminator
3. SCSI Device
4. SCSI Adapter
101
System board interrupt failure
1. System Board
102
System board timer error
1. System Board
106
1. System Board
110
System board memory parity error
1. Memory Module
2. System Board
111
I/O channel parity error
1. Reseat adapters
2. Any adapter
3. Riser card
4. System Board
114
Adapter ROM error
1. Adapter Memory
2. System Board
3. Riser card
129
Internal cache test error
1. Processor
2. L2 Cache Memory
3. System Board
151
Real-time clock failure
1. System Board
161
Bad CMOS battery
1. Run Setup
2. CMOS Backup Battery (see “Safety
Information” on page 125)
3. System Board
162
Configuration mismatch
1. Run Setup and verify Configuration
2. Had a device been added, removed,
changed location? If not, suspect that
device.
3. Power-on external devices first, then
power-on computer
4. CMOS Backup Battery (see “Safety
Information” on page 125)
System Board
5. System Board
6. Riser card
162
And unable to run diagnostics
1. Diskette Drive
2. System Board
3. Diskette Drive Cable
4. Riser card
60 Hardware Maintenance Manual A40 Type 6840 A40P Type 6841 A40i Type 2271: IBM NetVista Computer