IBM SL500 Personal Computer User Manual


 
Table 1. Numeric error codes (continued)
Symptom or error FRU or action, in sequence
8318
S.M.A.R.T. Capable but Command Failed
1. Hard disk drive.
2. System board.
3. SATA cable.
8319
S.M.A.R.T. Command Failed
1. Hard disk drive.
2. System board.
3. SATA cable.
831A
S.M.A.R.T. Status BAD, Backup and Replace
1. Hard disk drive.
2. System board.
3. SATA cable.
831B
S.M.A.R.T. Capable and Status BAD
1. Hard disk drive.
2. System board.
3. SATA cable.
8400
BootSector Write !!
Disconnect the system from the network.
There might be Virus on the system.
8401
VIRUS: Continue (Y/N)?
Disconnect the system from the network.
There might be Virus on the system.
8500
DMA-1 Error
System board.
8501
DMA-2 Error
System board.
8502
DMA Controller Error
System board.
8503
Checking NVRAM..Update Failed
System board.
8504
Microcode Error
Update the BIOS.
8505
NVRAM Checksum Bad, NVRAM Cleared
Set data by using the maintenance diskette.
If the same error still happens after setting
the data, replace the system board.
8506
Resource Conflict
After removing the option devices from the
system, if the same error still happens,
replace the system board.
8507
NVRAM Ignored
Set data by using the maintenance diskette.
8508
NVRAM Bad
Set data by using the maintenance diskette.
If the same error still happens the after
setting the data, replace the system board.
8509
Static Resource Conflict
After removing the option devices from the
system, if the same error still happens,
replace the system board.
850A
PCI I/O conflict
After removing the option devices from the
system, if the same error still happens,
replace the system board.
850B
PCI ROM conflict
After removing the option devices from the
system, if the same error still happens,
replace the system board.
850C
PCI IRQ conflict
After removing the option devices from the
system, if the same error still happens,
replace the system board.
Related service information 41