25
24
Addendum Required
If a two or five-digit addendum is enabled, then enabling this option
will require an addendum be present before a good read is registered. If
not, then symbols with and without the addendum will be accepted.
G1<ENTER>O for Addendum Required
G1<ENTER>P for Addendum Not Required
Add Separator Space
This option is used with the Two and Five-Digit Addendum options. If
enabled, an ASCII space character is inserted between the data de-
coded from the primary UPC symbol and the addendum symbol.
G1<ENTER>Q to Add Space Separator
G1<ENTER>R to Not Add Space Separator
EAN Settings:
Enable/Disable EAN-13
EAN-13 is a fixed format symbology and there are no variations
allowed. If enabled, EAN-13 symbology will be read, subject to the
reading restrictions specified by this set of options. If disabled, the
data from the symbology will be disregarded.
G2<ENTER>A for EAN-13 Enable
G2<ENTER>B for EAN-13 Disable
Enable/Disable EAN-8
If enabled, EAN-8 symbology will be read, subject to the reading
restrictions specified by this set of options. If disabled, the data from
the symbology will be disregarded.
G2<ENTER>C for EAN-8 Enable
G2<ENTER>D for EAN-8 Disable
Send Induced Country Code Character
The EAN symbology adds an extra digit to the beginning of the data to
create a two-digit country code. If enabled, the added induced charac-
ter is the first character transmitted. If disabled, the induced character
is not transmitted.
G2<ENTER>E for Induced Character Enable
G2<ENTER>F for Induced Character Disable
Send Check Digit
The check digit is mandatory in the EAN symbology. If enabled, the
reader will send the decoded check digit as the last character in the
data stream transmitted. If not, the check character will be suppressed
before transmission.
G2<ENTER>G for Send Check Digit
G2<ENTER>H for Do Not Send Check Digit