IDEAL INDUSTRIES IDEAL 5009-2 Paper Shredder User Manual


 
12
IDEAL 5009-1 • IDEAL 5009-2
05-03
5
7
9
2
4. Trouble shooting
Danger!
Disconnect from the mains before starting any
service work or before removing the cover.
Malfunction:
Standby (5) is not lighting up.
Cause:
- Main switch is OFF
- Emergency button is pressed.
- Key switch is vertical.
- Machine is not plugged in.
- On-site fuse.
- Motor protection switch from the
conveyor belt (9) operates.
- Machine is overloaded – The motor
protection switch is re-activated after
10 minutes.
Malfunction:
White light (2) illuminates, standby (5) is not
lighting up.
Cause:
- Door is open.
- Grid is open.
- Conveyor belt (accessory) is not locked.
Malfunction:
Machine door is difficult to open.
Cause:
Guiding bar of the lower cutting head cover is
dirty
Remedy:
Clean and grease the guiding bar. Do not use
grease or oil containing resin.
Malfunction:
Motor hums and has no power.
Cause:
One phase is missing.
Remedy:
Ensure that voltage is on all 3 phases.