2.3 Power supply
The rating plate is located at the rear of the
machine.
- Data stated on the rating plate
- Voltage “V“,
- Frequency “Hz“,
- Power consumption “A“ must correspond to the
values of the power supply unit.
- Earth wire must be available.
- Connect the machine to the mains.
2.4 Checking rotating direction
Operate the machine for a short time as described
under 3. “Operation“.
- The material is transported to the shredding
mechanism by a feeding belt.
Feeding belt runs in the opposite direction.
The machine is wired according to the UEC rotary
field standard. When changing the rotary direction
we recommend that this is performed by an
experienced specialist. The rotary direction may
also be changed by exchanging the “L1“ and “L2“
connections in the plug.
Danger!
Incorrect exchanging of connections may
endanger the operator. If in doubt, this work
should be performed by an electrical specialist.