Replacing the projection lamp
The lamp hour timer in the Service Info menu counts the number of hours
the lamp has been in use. Twenty hours before the specified end of the
lamp’s life, the message “Change lamp” briefly appears on the projected
screen.
NOTE: You can order new lamp housings from www.infocus.com (in select
areas), your retailer or your dealer. Only genuine InFocus lamps are tested
for use in this projector. InFocus is not liable for the performance, safety or
certification of any other lamps. The use of other lamps violates the projec-
tor warranty and voids all certification marks on this projector.
1 Turn off the projector and unplug the power cable.
2 Wait 45 minutes to allow the projector to cool thoroughly.
3 Loosen the lamp cover screw on the right side of the projector (marked
by the arrow) then slide and lift the lamp cover off.
WARNINGS:
To avoid burns, allow the projector to cool for at least 45 minutes before
you replace the lamp.
Only genuine InFocus lamps are tested with this projector. Use of other
lamps may cause electrical shock and fire.
To prevent eye injury if the projector is ceiling mounted, wear protec-
tive eyewear before opening lamp door. A warning sticker is included
with the user documentation. Place this sticker on the lamp door if the
projector is mounted on the ceiling.
Do not drop the lamp module. The glass may shatter and cause injury.
Do not touch the glass lamp screen. Fingerprints can obscure projection
sharpness.
Be extremely careful when removing the lamp housing. In the unlikely
event that the bulb ruptures, small glass fragments may be generated.
The lamp housing is designed to contain these fragments, but use cau-
tion when removing the lamp housing. Before replacing the lamp, clean
the lamp compartment and dispose of cleaning materials. Wash hands
after lamp replacement.
Hg – Lamp contains mercury. Manage in accordance with local
disposal laws. See www.lamprecycle.org.