WARNINGS:
To avoid burns, allow the projector to cool for at least 60 minutes before
you replace the lamp.
Do not drop the lamp module. The glass may shatter and cause injury.
Do not touch the glass lamp screen. Fingerprints can obscure projection
sharpness.
Be extremely careful when removing the lamp housing. In the unlikely
event that the lamp ruptures, small glass fragments may be generated.
The lamp module is designed to contain most of these fragments, but
use caution when removing it.
5 Carefully remove the lamp module by grasping and lifting the metal
bail wire. Dispose of the lamp in an environmentally proper manner.
6 Install the new lamp module, making sure that it is properly seated.
7 Tighten the three screws.
8 Replace the lamp door by inserting the tabs into the tab bays and tight-
ening the two screws.
9 Plug in the power cable, press the power switch then press the Power
button to turn the projector back on.
10 Reset the lamp hour timer.
Resetting the lamp timer
After replacing the lamp, reset the lamp timer. Navigate to the Set-
tings>Service menu and select Lamp Reset to reset the lamp timer.
remove module using bail wire
reset lamp time in Service menu