4657-7744-12
Checking and Adjusting the Paper Reference Position
NOTE
Perform the procedure below after adjusting the paper reference positions for the paper
feed unit and the large-capacity cabinet.
1. Display the Tech. Rep. Mode screen.
(For details about displaying the Tech. Rep.
Mode screen, refer to the Service Manual.)
2. Touch “Machine Adjust”.
3. Touch “PRT Area”.
4. Touch “Dup. Left Margin”.
5. Touch “1st.”.
6. Press the Start key.
A test page is printed.
7. Measure the width of loss for the test pattern
printed on the back of the test page.
NOTE
Do not measure from the back of the test
pattern.
Standard width (a): 3.0 mm ± 1.0 mm
If the measured width of loss does not meet
its standard width, touch and in the
lower-right corner of the screen to adjust the
width.
Print another test page and check the printed
image.
C4658P001CA
C4659P004CA
C4657P001CA
C4657P002CA
C4004O068CA
C4657U014AA
a
NEXT