12.1 ENVIRONMENTAL SPECIFICATIONS
Rugged
Class
Grade
Operating
Temp.
Storage
Temp
Vibration Shock Humidity
Other
Specs
C1
Commercial
0ºC to +65ºC
200 linear
ft/minute air
flow
-50C to
+100C
N/A
N/A
Operating: Up
to 90% Non-
Condensing
Conformal
coated: No
Altitude:
33,000 ft.
R1
Rugged,
Forced Air
-20ºC to +75ºC
350 linear
ft/minute air
flow
-50C to
+100C
5Hz-2000Hz
at 2g,
0.38mm
peak
displacement
(operating)
5Hz-2000Hz
at 5g,
0.76mm
peak
displacement
(non-
operating
Per MIL-
STD-810E
20g, 11ms, ½
sine
(operating);
30g, 11ms, ½
sine (non-
operating)
Per MIL-STD-
810E
Operating: Up
to 95% Non-
Condensing
Conformal
coated: Yes
Altitude:
50,000 ft.
R2
Rugged,
Forced Air
-40ºC to +85ºC
450 linear
ft/minute air
flow
-50C to
+100C
5Hz-2000Hz
at 2g,
0.38mm
peak
displacement
(operating)
5Hz-2000Hz
at 5g,
0.76mm
peak
displacement
(non-
operating
Per MIL-
STD-810E
30g, 11ms, ½
sine
(operating);
40g, 11ms, ½
sine (non-
operating)
Per MIL-STD-
810E
Operating: Up
to 95% Non-
Condensing
Conformal
coated: Yes
Altitude:
50,000 ft.
Note: Conformal coating is MIL-I-46058 compliant (typically type UR or AR) or other as applicable