Intel SSR212MC2 Server User Manual


 
Hardware Specific Information StorView* Enclosure Management Software User Guide
Revision 1.1
18
Object State Related Meaning Required Action
Fan Light Constant
On
Varying levels of
beep and
chassis fault light
setting. No beep
if muted.
Fan broken or out
of tolerance.
Replace Fans
immediately.
Flashing Fan Ident On. -
Drive Light
(amber)
Constant
On
Varying levels of
beep and
chassis fault –
usually slow
beep and slow
flash. No beep if
muted.
Drive faulty. Replace drive.
Flashing Drive Ident On. -
Chassis Ident
LED
Flashing Chassis Ident On -
Buzzer Off Chassis fault
LED off.
No issues. No action required.
Off Chassis fault
LED flashing or
constant.
Muted. See Chassis LED
settings above for
interpretation of lights
and remedy.
Intermittent
short beep
(0.5s beep
every 32s).
Various chassis
fault light flash
states.
Fault has occurred
and system is
muted but in
remind mode.
Check fault status using
chassis fault LED
settings and remedy.
Slow beep
(0.5s beep
every 8s).
Chassis fault
LED slow blink
(0.5s on, 3.5s
off).
Warning Mode. See chassis fault LED
settings above.
Faster beep
(1.5s beep,
0.5s
silence).
Chassis fault
LED fast Blink
(alternating every
0.5s).
Critical Mode. See chassis fault LED
settings above.
Constant
beep.
Chassis fault
LED constant on.
Failure Mode. See chassis fault LED
settings above.