Juniper Networks 5000 SERIES Power Supply User Manual


 
Configuring the Chassis Alarm
NetScreen-5000 Series 31
For example, if you assigned the MGT interface an IP address of
10.100.2.183
/16, enter the following:
http://10.100.2.183
The NetScreen WebUI software displays the login prompt.
3. Enter netscreen in both the Admin Name and Password fields, then click
Login. (Use lowercase letters only. The Admin Name and Password fields are
both case sensitive.)
The NetScreen WebUI application window appears.
C
ONFIGURING
THE
C
HASSIS
A
LARM
The NetScreen-5000 Series device allows you to configure the chassis alarm, an audible
warning that sounds when a system failure or hazardous event occurs. To determine
which failures and events trigger the chassis alarm:
1. Configure the audible alarms by executing the following command:
set chassis audible-alarm string
where string can be any of the following keywords:
2. After configuring the alarm, it is advisable to view alarm environment
information by executing the following command:
get chassis
all Enables all chassis alarms.
battery Sets the chassis alarm to sound when a battery fails.
fan-failed Sets the chassis alarm to sound when a fan fails.
power-failed Sets the chassis alarm to sound when a power supply fails.
temperature Sets the chassis alarm to sound when the temperature goes outside of
the acceptable range.