Kodak 2500 Scanner User Manual


 
A-63055 December 1999 21
Read Deskew Data
Enable Read Deskew Data to detect the skewing of a document and
notify the application when a skewed document occurs.
NOTE:
Read Deskew Data
is not available when
Long Paper
is
enabled.
Detect Double Feed
When Detect Double Feed is enabled, multiple feed documents (two
or more documents scanned simultaneously) will be detected.
Sensitivity—when you enable
Detect Double Feed
,
Sensitivity
is also
enabled. Select one of the following detection sensitivities:
High—select this when you scan thick paper.
Low—select this when you scan thin paper.
Normal—select this when you scan standard paper.
NOTES: The scanner uses an ultrasonic wave to detect multiple feed
documents. Document thickness and wrinkles may cause
false reads.
When you scan important documents, check the number of
sheets of a document and the number of scanned images to
verify that all documents have been scanned.
Slow Feeding
Slow Feeding allows you to change the feeder speed in order to scan
a thin, folded, creased, or curled document in the automatic document
feeder. Before scanning, straighten the document and select the
Slow
Feeding
check box.
NOTE: Enable
Slow Feeding
when
Long Paper
is selected.