Kodak 7020 Projector User Manual


 
34
Possible problems during operation
Note: If none of the faults listed above caused the problem, please contact your KODAK audiovisual products dealer.
3UREOHP 3RVVLEOHUHDVRQV +HOS
After switching on, the projector is not
operable. No defect is indicated by the red
LED.
Fuse (primary or secondary) blown. Check fuse and possibly replace it.
For UK users: Check 13 A plug fuse also.
EKTAPRO 7020/9020: After switching on,
the tray is moved (to 0-position) and the
projector is switched off.
The projector is in "silent mode" (no
defect).
Press transport button and the projector will leave the silent mode (see.
page 24).
Red LED is flashing, and all functions
are blocked (after switching-on or during
operation).
Projector drive system failure (tray
transportation, slide lift):
1. Jammed slide in the slide gate.
2. Slide tray base plate not in the zero
position.
3. Slide tray base plate bent.
4.Tray setting switch is not set correctly!
1. Switch off projector; lift off slide tray; remove slide from the slide
gate; rotate the base plate until it locks in position; replace the tray and
switch on the projector.
2. Switch off projector; lift off slide tray, rotate the base plate until it
locks in position; replace tray and switch on the projector.
3. Use a new slide tray.
4. Switch off projector; lift off slide tray, rotate the base plate until it
locks in position; set tray setting switch to correct position (see page 24);
replace tray and switch on the projector.
Image can’t be focused by focus buttons. 1. Lens mount was not set to its default
position.
2. Slide is distorted
3. Slide mount is defective.
1. Press focus buttons to move lens mount to its default setting. Focus the
image as indicated in the manual.
2. Use glass mounted slides.
3. Replace slide mount.
The tray cannot be fit on the tray transport
ring
Tray transport ring not in zero position. - Hold slide change buttons depressed till tray stops in zero-position or
- switch projector off and then on again.
The tray cannot be moved. Tray has not been placed correctly on the
transport ring.
Lift off the tray; switch projector on and then off again and then replace
tray.
Slides are one-sided illuminated. Condensor out of position. Switch off the projector; pull out the lamp module and let it cool down;
check that the condensor is correctly seated and push back into position if
necessary.
Fan runs but lamp is switched off. 1. Lamp failure
2. Lamp module is not properly fixed.
1. Refer to page 32
2. Refer to page 32
Even if autofocus is switched on, the
image is not in focus.
1. Lens mount was not set to its default
position.
2. Slide is distorted.
3. Slide mount is defective.
4. Slide in the 0-compartment of the tray
1. Switch autofocus off, move the lens mount to its middle position (s.
page 26, switch on the autofocus and focus the image.
2. Use glass mounted slides.
3. Replace slide mount.
4. Remove slide from the 0-compartment. (If necessary, further
information can be requested from Kodak).
After switching on the EKTAPRO 9020
Slide Projector the tray is permanently
transported from the 0-position to the 1-
position and vice versa.
Timer and the switch for slide tray zeroing
is switched on.
Switch off timer and/or switch for slide tray zeroing.