13. When turning the projector off, rotate the operating switch counter
clockwise one step. The lamp will go off, but the fan will continue
to operate. Allow the fan to operate for a few minutes to properly
cool the bulb, then shut off the fan by turning the operating switch
to the OFF position. Turn the power switch to the OFF position.
For added safety, your projector has a built-in fan/delay circuit. If
you turn the projector completely off without cooling the lamp, the
temperature probe will keep the fan running until the projector
cools down.
The flat mirror in the 560 Series is aluminum coated and works as a
surface reflecting mirror. In the 750 Series, there is a heat absorbing flat
mirror.
Take care not to leave finger prints, stains or scratches on the surface of
the elliptical mirror, the flat mirror or the Xenon bulb.
If the mirrors are smudged or stained, wipe them off gently with a lens
cleaner or a piece of gauze wetted with a mixture of alcohol and ether.
Connect the standard Kodak Ektgraphic-III Remote Control to the round,
5-pin remote control socket on the rear of the projector. This will allow
you to control forward/reverse and focus.
REMOTE-1 Connector (DIN 5P)
This connector is used with standard Kodak Ektagraphic
-III Remote
Controls.
1. Focus In
2. Slide Forward
3. Slide Reverse
4. Focus Out
5. COM
Cleaning the Mirrors &
Optical System
Remote Control
Operating the Unit & Remote Control
14
Flat Mirror
Xenon Bulb
Magnet Assembly
Elliptical Mirror
Housing
Insulation Plate
3
5
4
1
2