Kodak i60 Scanner User Manual


 
A-61182 October 2001 29
Replacing the ADF
snap-in feed module
After approximately 100,000 pages have been scanned through the ADF, the
separation pad may become worn and cause document feeding problems. In this
case, you should replace the feed module.
Four replacement ADF snap-in feed modules are included with your scanner. To order
more feed modules, consult your dealer or order online at www.kodak.com/go/shop
(order KODAK Feed Module for Scanners i50/i60; catalog number 181-4300.)
Follow the procedure below to replace the feed module.
1. Open the ADF.
2. Remove the ADF snap-in feed module by pinching the gray tabs.
3. Pull out the upper part of the pad clamp.
4. Take the ADF feed module out of its box.
5. Hold the upper part of the pad clamp and place it on the pad holder.
6. Close the ADF.
The scanner is now ready for use.
ADF
Upper part of
ADF pad clamp
ADF feed module
Upper part of
ADF pad clamp